Xigmatek NRP-PC402 400W Review
paulktreg - July 13, 2009» Discuss this article (8)
Testing:
For more information on how we test our power supplies, please browse our testing methodology.
Electrical Safety:
|
Electrical Safety Test Class 1
|
|
|
Manufacturer/Model
|
Pass/Fail
|
|
Xigmatek NRP-PC402
|
Pass
|
Short Circuit Protection:
I short circuited the 3V3, 5V0 and both 12V lines in turn. The power supply did shut down, and once the short was removed and the unit switched off for at least one second, resumed normal operation. Although listed here at the beginning of the testing section, I tend to leave this test until the very end, in case it doesn't quite go to plan.
DC Output Voltage Load Regulation:
Mains Input Voltage 110VAC
|
DC Output Voltage Load Regulation
|
|
|
AC Supply = 110V / DC Load = 0W
|
|
|
PSU DC Rail
|
Measured Voltage(V)
|
|
3V3
|
3.36
|
|
5V0
|
4.98
|
|
12V1
|
12.09
|
|
12V2
|
12.09
|
|
-12V
|
-11.71
|
|
5VSB
|
5.00
|
|
DC Output Voltage Load Regulation
|
|||||
|
AC Supply = 110V / DC Load = 110W (27% of Rated Maximum Output Power)
|
|||||
|
PSU
DC Line
|
Measured
Voltage(V)
|
Measured
Current (A)
|
Load Power
(W)
|
ATX12V V Limits
(V)
|
Pass/Fail
|
|
+3V3
|
3.37
|
3.13
|
10.55
|
3.135 – 3.465
|
Pass
|
|
+5V0
|
4.94
|
4.54
|
22.43
|
4.75 – 5.25
|
Pass
|
|
+12V0(1)
|
12.21
|
2.57
|
31.38
|
11.4 – 12.6
|
Pass
|
|
+12V0(2)
|
12.21
|
2.58
|
31.50
|
11.4 – 12.6
|
Pass
|
|
-12V0
|
11.42
|
0.34
|
3.88
|
10.8 – 13.2
|
Pass
|
|
+5VSB
|
4.98
|
2.02
|
10.06
|
4.75 – 5.25
|
Pass
|
|
TOTAL POWER SUPPLY DC LOAD =
|
110W
|
|
|||
|
DC Output Voltage Load Regulation
|
|||||
|
AC Supply = 110V / DC Load = 216W (54% of Rated Maximum Output Power)
|
|||||
|
PSU
DC Line
|
Measured
Voltage(V)
|
Measured
Current (A)
|
Load Power
(W)
|
ATX12V V Limits
(V)
|
Pass/Fail
|
|
+3V3
|
3.36
|
7.79
|
26.78
|
3.135 – 3.465
|
Pass
|
|
+5V0
|
4.90
|
8.46
|
41.45
|
4.75 – 5.25
|
Pass
|
|
+12V0(1)
|
12.34
|
2.60
|
32.08
|
11.4 – 12.6
|
Pass
|
|
+12V0(2)
|
12.31
|
8.24
|
101.43
|
11.4 – 12.6
|
Pass
|
|
-12V0
|
11.61
|
0.35
|
4.06
|
10.8 – 13.2
|
Pass
|
|
+5VSB
|
4.98
|
2.02
|
10.06
|
4.75 – 5.25
|
Pass
|
|
TOTAL POWER SUPPLY DC LOAD =
|
216W
|
|
|||
|
DC Output Voltage Load Regulation
|
|||||
|
AC Supply = 110V / DC Load = 406W (101% of Rated Maximum Output Power)
|
|||||
|
PSU
DC Line
|
Measured
Voltage(V)
|
Measured
Current (A)
|
Load Power
(W)
|
ATX12V V Limits
(V)
|
Pass/Fail
|
|
+3V3
|
3.36
|
12.13
|
40.76
|
3.135 – 3.465
|
Pass
|
|
+5V0
|
4.88
|
12.73
|
62.12
|
4.75 – 5.25
|
Pass
|
|
+12V0(1)
|
12.38
|
11.63
|
143.98
|
11.4 – 12.6
|
Pass
|
|
+12V0(2)
|
12.37
|
11.73
|
145.10
|
11.4 – 12.6
|
Pass
|
|
-12V0
|
11.86
|
0.36
|
4.27
|
10.8 – 13.2
|
Pass
|
|
+5VSB
|
4.97
|
2.02
|
10.04
|
4.75 – 5.25
|
Pass
|
|
TOTAL POWER SUPPLY DC LOAD =
|
406W
|
|
|||
Mains Input Voltage 230VAC
|
DC Output Voltage Load Regulation
|
|
|
AC Supply = 230V / DC Load = 0W
|
|
|
PSU DC Rail
|
Measured Voltage(V)
|
|
3V3
|
3.36
|
|
5V0
|
4.98
|
|
12V1
|
12.09
|
|
12V2
|
12.09
|
|
-12V
|
-11.71
|
|
5VSB
|
5.05
|
|
DC Output Voltage Load Regulation
|
|||||
|
AC Supply = 230V / DC Load = 110W (27% of Rated Maximum Output Power)
|
|||||
|
PSU
DC Line
|
Measured
Voltage(V)
|
Measured
Current (A)
|
Load Power
(W)
|
ATX12V V Limits
(V)
|
Pass/Fail
|
|
+3V3
|
3.37
|
3.14
|
10.55
|
3.135 – 3.465
|
Pass
|
|
+5V0
|
4.94
|
4.49
|
22.18
|
4.75 – 5.25
|
Pass
|
|
+12V0(1)
|
12.21
|
2.57
|
31.38
|
11.4 – 12.6
|
Pass
|
|
+12V0(2)
|
12.21
|
2.58
|
31.50
|
11.4 – 12.6
|
Pass
|
|
-12V0
|
11.43
|
0.34
|
3.88
|
10.8 – 13.2
|
Pass
|
|
+5VSB
|
4.98
|
2.02
|
10.06
|
4.75 – 5.25
|
Pass
|
|
TOTAL POWER SUPPLY DC LOAD =
|
110W
|
|
|||
|
DC Output Voltage Load Regulation
|
|||||
|
AC Supply = 230V / DC Load = 217W (54% of Rated Maximum Output Power)
|
|||||
|
PSU
DC Line
|
Measured
Voltage(V)
|
Measured
Current (A)
|
Load Power
(W)
|
ATX12V V Limits
(V)
|
Pass/Fail
|
|
+3V3
|
3.36
|
7.99
|
26.85
|
3.135 – 3.465
|
Pass
|
|
+5V0
|
4.89
|
8.63
|
42.20
|
4.75 – 5.25
|
Pass
|
|
+12V0(1)
|
12.32
|
2.60
|
32.03
|
11.4 – 12.6
|
Pass
|
|
+12V0(2)
|
12.35
|
8.26
|
102.01
|
11.4 – 12.6
|
Pass
|
|
-12V0
|
11.62
|
0.35
|
4.07
|
10.8 – 13.2
|
Pass
|
|
+5VSB
|
4.98
|
2.02
|
10.06
|
4.75 – 5.25
|
Pass
|
|
TOTAL POWER SUPPLY DC LOAD =
|
217W
|
|
|||
|
DC Output Voltage Load Regulation
|
|||||
|
AC Supply = 110V / DC Load = 401W (100% of Rated Maximum Output Power)
|
|||||
|
PSU
DC Line
|
Measured
Voltage(V)
|
Measured
Current (A)
|
Load Power
(W)
|
ATX12V V Limits
(V)
|
Pass/Fail
|
|
+3V3
|
3.36
|
11.99
|
40.29
|
3.135 – 3.465
|
Pass
|
|
+5V0
|
4.89
|
12.36
|
60.44
|
4.75 – 5.25
|
Pass
|
|
+12V0(1)
|
12.35
|
11.52
|
142.27
|
11.4 – 12.6
|
Pass
|
|
+12V0(2)
|
12.34
|
11.66
|
143.88
|
11.4 – 12.6
|
Pass
|
|
-12V0
|
11.85
|
0.36
|
4.26
|
10.8 – 13.2
|
Pass
|
|
+5VSB
|
4.97
|
2.02
|
10.04
|
4.75 – 5.25
|
Pass
|
|
TOTAL POWER SUPPLY DC LOAD =
|
401W
|
|
|||
The Xigmatek NRP-PC402 managed to maintain its rails within the limits set by the ATX12V V2.2 specification at all load levels. No problems here, so let's move on.