Testing:
For more information on how we test our power supplies, please browse our testing methodology.
Electrical Safety:
|
Electrical Safety Test Class 1
|
|
|
Manufacturer/Model
|
Pass/Fail
|
|
Ultra X4 1050W
|
Pass
|
Short Circuit Protection:
I short circuited the 3V3, 5V0 and 12V rails in turn. The power supply did shut down, and once the short was removed and the unit switched off for at least one second, resumed normal operation. Although listed here at the beginning of the testing section, I tend to leave this test until the very end, in case it doesn't quite go to plan.
DC Output Voltage Load Regulation:
Mains Input Voltage 110VAC
|
Ultra X4 1050W
|
|
|
DC Output Voltage Load Regulation
|
|
|
AC Supply = 110V / DC Load = 0W
|
|
|
PSU DC Rail
|
Measured Voltage(V)
|
|
3V3
|
3.40
|
|
5V0
|
4.91
|
|
+12V
|
12.41
|
|
-12V
|
-11.95
|
|
5VSB
|
5.01
|
|
Ultra X4 1050W
|
|||||
|
DC Output Voltage Load Regulation
|
|||||
|
110VAC - Total Load at 202W which is 19% of Rated Maximum Output Power
|
|||||
|
PSU
DC Rail
|
Measured
Voltage(V)
|
Measured
Current (A)
|
Load Power
(W)
|
ATX12V V Limits
(V)
|
Pass/Fail
|
|
+3V3
|
3.40
|
3.15
|
10.71
|
3.135 – 3.465
|
Pass
|
|
+5V
|
5.14
|
9.33
|
47.96
|
4.75 – 5.25
|
Pass
|
|
+12V
|
12.39
|
10.42
|
129.10
|
11.4 – 12.6
|
Pass
|
|
-12V
|
11.97
|
0.34
|
4.07
|
10.8 – 13.2
|
Pass
|
|
+5VSB
|
4.93
|
1.98
|
9.76
|
4.75 – 5.25
|
Pass
|
|
Total Power Supply Loading
|
202W
|
|
|||
|
Ultra X4 1050W
|
|||||
|
DC Output Voltage Load Regulation
|
|||||
|
110VAC - Total Load at 525W which is 50% of Rated Maximum Output Power
|
|||||
|
PSU
DC Rail
|
Measured
Voltage(V)
|
Measured
Current (A)
|
Load Power
(W)
|
ATX12V V Limits
(V)
|
Pass/Fail
|
|
+3V3
|
3.39
|
8.02
|
27.19
|
3.135 – 3.465
|
Pass
|
|
+5V
|
5.13
|
9.32
|
47.81
|
4.75 – 5.25
|
Pass
|
|
+12V
|
12.36
|
35.25
|
435.69
|
11.4 – 12.6
|
Pass
|
|
-12V
|
12.12
|
0.36
|
4.36
|
10.8 – 13.2
|
Pass
|
|
+5VSB
|
4.93
|
1.99
|
9.81
|
4.75 – 5.25
|
Pass
|
|
Total Power Supply Loading
|
525W
|
|
|||
|
Ultra X4 1050W
|
|||||
|
DC Output Voltage Load Regulation
|
|||||
|
110VAC - Total Load at 1063W which is 101% of Rated Maximum Output Power
|
|||||
|
PSU
DC Rail
|
Measured
Voltage(V)
|
Measured
Current (A)
|
Load Power
(W)
|
ATX12V V Limits
(V)
|
Pass/Fail
|
|
+3V3
|
3.38
|
14.12
|
47.73
|
3.135 – 3.465
|
Pass
|
|
+5V
|
5.12
|
16.33
|
83.61
|
4.75 – 5.25
|
Pass
|
|
+12V
|
12.32
|
74.52
|
918.09
|
11.4 – 12.6
|
Pass
|
|
-12V
|
12.32
|
0.36
|
4.36
|
10.8 – 13.2
|
Pass
|
|
+5VSB
|
4.92
|
1.99
|
9.81
|
4.75 – 5.25
|
Pass
|
|
Total Power Supply Loading
|
1063W
|
|
|||
Mains Input Voltage 230VAC
|
Ultra X4 1050W
|
|
|
DC Output Voltage Load Regulation
|
|
|
AC Supply = 230V / DC Load = 0W
|
|
|
PSU DC Rail
|
Measured Voltage(V)
|
|
3V3
|
3.40
|
|
5V0
|
4.91
|
|
+12V
|
12.41
|
|
-12V
|
-11.95
|
|
5VSB
|
5.10
|
|
Ultra X4 1050W
|
|||||
|
DC Output Voltage Load Regulation
|
|||||
|
230VAC - Total Load at 202W which is 19% of Rated Maximum Output Power
|
|||||
|
PSU
DC Rail
|
Measured
Voltage(V)
|
Measured
Current (A)
|
Load Power
(W)
|
ATX12V V Limits
(V)
|
Pass/Fail
|
|
+3V3
|
3.40
|
3.16
|
10.74
|
3.135 – 3.465
|
Pass
|
|
+5V
|
5.14
|
9.36
|
48.11
|
4.75 – 5.25
|
Pass
|
|
+12V
|
12.39
|
10.42
|
129.10
|
11.4 – 12.6
|
Pass
|
|
-12V
|
11.96
|
0.34
|
4.07
|
10.8 – 13.2
|
Pass
|
|
+5VSB
|
4.94
|
1.98
|
9.78
|
4.75 – 5.25
|
Pass
|
|
Total Power Supply Loading
|
202W
|
|
|||
|
Ultra X4 1050W
|
|||||
|
DC Output Voltage Load Regulation
|
|||||
|
230VAC - Total Load at 526W which is 50% of Rated Maximum Output Power
|
|||||
|
PSU
DC Rail
|
Measured
Voltage(V)
|
Measured
Current (A)
|
Load Power
(W)
|
ATX12V V Limits
(V)
|
Pass/Fail
|
|
+3V3
|
3.40
|
8.10
|
27.54
|
3.135 – 3.465
|
Pass
|
|
+5V
|
5.13
|
9.33
|
47.86
|
4.75 – 5.25
|
Pass
|
|
+12V
|
12.36
|
35.33
|
436.68
|
11.4 – 12.6
|
Pass
|
|
-12V
|
12.12
|
0.36
|
4.36
|
10.8 – 13.2
|
Pass
|
|
+5VSB
|
4.93
|
1.99
|
9.81
|
4.75 – 5.25
|
Pass
|
|
Total Power Supply Loading
|
526W
|
|
|||
|
Ultra X4 1050W
|
|||||
|
DC Output Voltage Load Regulation
|
|||||
|
230VAC - Total Load at 1064W which is 101% of Rated Maximum Output Power
|
|||||
|
PSU
DC Rail
|
Measured
Voltage(V)
|
Measured
Current (A)
|
Load Power
(W)
|
ATX12V V Limits
(V)
|
Pass/Fail
|
|
+3V3
|
3.38
|
14.02
|
47.39
|
3.135 – 3.465
|
Pass
|
|
+5V
|
5.12
|
15.79
|
80.84
|
4.75 – 5.25
|
Pass
|
|
+12V
|
12.32
|
74.83
|
921.90
|
11.4 – 12.6
|
Pass
|
|
-12V
|
12.37
|
0.36
|
4.45
|
10.8 – 13.2
|
Pass
|
|
+5VSB
|
4.92
|
1.99
|
9.79
|
4.75 – 5.25
|
Pass
|
|
Total Power Supply Loading
|
1064W
|
|
|||
No problems here. All voltages fall well within the ATX12V V2.2 specification.