Welcome Stranger to OCC!Login | Register

Ultra X4 1050W Power Supply Review

paulktreg    -   October 18, 2009
» Discuss this article (0)

Lowest Prices

Testing:

For more information on how we test our power supplies, please browse our testing methodology.

 

 

 

 

 

 

 

 

 

 

 

 

  

 

 

Electrical Safety:

 

Electrical Safety Test Class 1
Manufacturer/Model
Pass/Fail
Ultra X4 1050W
Pass

 

Short Circuit Protection:

I short circuited the 3V3, 5V0 and 12V rails in turn. The power supply did shut down, and once the short was removed and the unit switched off for at least one second, resumed normal operation. Although listed here at the beginning of the testing section, I tend to leave this test until the very end, in case it doesn't quite go to plan.

 

DC Output Voltage Load Regulation:

 

Mains Input Voltage 110VAC

 

 

Ultra X4 1050W
DC Output Voltage Load Regulation
AC Supply = 110V / DC Load = 0W
PSU DC Rail
Measured Voltage(V)
3V3
3.40
5V0
4.91
+12V
12.41
-12V
-11.95
5VSB
5.01

 

Ultra X4 1050W
DC Output Voltage Load Regulation
110VAC - Total Load at 202W which is 19% of Rated Maximum Output Power
PSU
DC Rail
Measured
Voltage(V)
Measured
Current (A)
Load Power
(W)
ATX12V V Limits
(V)
Pass/Fail
+3V3
3.40
3.15
10.71
3.135 – 3.465
Pass
+5V
5.14
9.33
47.96
4.75 – 5.25
Pass
+12V
12.39
10.42
129.10
11.4 – 12.6
Pass
-12V
11.97
0.34
4.07
10.8 – 13.2
Pass
+5VSB
4.93
1.98
9.76
4.75 – 5.25
Pass
Total Power Supply Loading
202W
 

 

Ultra X4 1050W
DC Output Voltage Load Regulation
110VAC - Total Load at 525W which is 50% of Rated Maximum Output Power
PSU
DC Rail
Measured
Voltage(V)
Measured
Current (A)
Load Power
(W)
ATX12V V Limits
(V)
Pass/Fail
+3V3
3.39
8.02
27.19
3.135 – 3.465
Pass
+5V
5.13
9.32
47.81
4.75 – 5.25
Pass
+12V
12.36
35.25
435.69
11.4 – 12.6
Pass
-12V
12.12
0.36
4.36
10.8 – 13.2
Pass
+5VSB
4.93
1.99
9.81
4.75 – 5.25
Pass
Total Power Supply Loading
525W
 

 

Ultra X4 1050W
DC Output Voltage Load Regulation
110VAC - Total Load at 1063W which is 101% of Rated Maximum Output Power
PSU
DC Rail
Measured
Voltage(V)
Measured
Current (A)
Load Power
(W)
ATX12V V Limits
(V)
Pass/Fail
+3V3
3.38
14.12
47.73
3.135 – 3.465
Pass
+5V
5.12
16.33
83.61
4.75 – 5.25
Pass
+12V
12.32
74.52
918.09
11.4 – 12.6
Pass
-12V
12.32
0.36
4.36
10.8 – 13.2
Pass
+5VSB
4.92
1.99
9.81
4.75 – 5.25
Pass
Total Power Supply Loading
1063W
 

 

Mains Input Voltage 230VAC

 

 

Ultra X4 1050W
DC Output Voltage Load Regulation
AC Supply = 230V / DC Load = 0W
PSU DC Rail
Measured Voltage(V)
3V3
3.40
5V0
4.91
+12V
12.41
-12V
-11.95
5VSB
5.10

 

Ultra X4 1050W
DC Output Voltage Load Regulation
230VAC - Total Load at 202W which is 19% of Rated Maximum Output Power
PSU
DC Rail
Measured
Voltage(V)
Measured
Current (A)
Load Power
(W)
ATX12V V Limits
(V)
Pass/Fail
+3V3
3.40
3.16
10.74
3.135 – 3.465
Pass
+5V
5.14
9.36
48.11
4.75 – 5.25
Pass
+12V
12.39
10.42
129.10
11.4 – 12.6
Pass
-12V
11.96
0.34
4.07
10.8 – 13.2
Pass
+5VSB
4.94
1.98
9.78
4.75 – 5.25
Pass
Total Power Supply Loading
202W
 

 

Ultra X4 1050W
DC Output Voltage Load Regulation
230VAC - Total Load at 526W which is 50% of Rated Maximum Output Power
PSU
DC Rail
Measured
Voltage(V)
Measured
Current (A)
Load Power
(W)
ATX12V V Limits
(V)
Pass/Fail
+3V3
3.40
8.10
27.54
3.135 – 3.465
Pass
+5V
5.13
9.33
47.86
4.75 – 5.25
Pass
+12V
12.36
35.33
436.68
11.4 – 12.6
Pass
-12V
12.12
0.36
4.36
10.8 – 13.2
Pass
+5VSB
4.93
1.99
9.81
4.75 – 5.25
Pass
Total Power Supply Loading
526W
 

 

Ultra X4 1050W
DC Output Voltage Load Regulation
230VAC - Total Load at 1064W which is 101% of Rated Maximum Output Power
PSU
DC Rail
Measured
Voltage(V)
Measured
Current (A)
Load Power
(W)
ATX12V V Limits
(V)
Pass/Fail
+3V3
3.38
14.02
47.39
3.135 – 3.465
Pass
+5V
5.12
15.79
80.84
4.75 – 5.25
Pass
+12V
12.32
74.83
921.90
11.4 – 12.6
Pass
-12V
12.37
0.36
4.45
10.8 – 13.2
Pass
+5VSB
4.92
1.99
9.79
4.75 – 5.25
Pass
Total Power Supply Loading
1064W
 

 

No problems here. All voltages fall well within the ATX12V V2.2 specification.

 




  1. Introduction & Closer Look
  2. Closer Look (The Power Supply)
  3. Specification & Features
  4. Testing: DC Voltage Load Regulation At 110VAC & 230VAC
  5. Testing: Efficiency, Power Factor & DC Quality
  6. Testing: Temperature, Noise Level & Fan Speed
  7. Conclusion
Random Pic