Testing:

For more information on how we test our power supplies, please browse our testing methodology.

 

Short Circuit Protection:

I short circuited the 3V3, 5V0 and the 12V rail(s) in turn. The power supply did shut down, and once the short was removed and the unit switched off for at least one second, resumed normal operation. Although listed here at the beginning of the testing section, I tend to leave this test until the very end, in case it doesn't quite go to plan.

 

DC Output Voltage Load Regulation:

 

Mains Input Voltage 110VAC

 

 

 

 

 

 

 

 

Thermaltake Toughpower Grand 1200W (TPG-1200M) DC Output Voltage Load Regulation
Supply = 115VAC/50Hz
PSU DC Rail
Rail Loading
Measured Voltage
Permitted Regulation
Actual Regulation
+3.3V
0
3.38V
±5%
+2.4%
+5V
0
4.99V
±5%
-0.2%
+12V1
0
12.26V
±5%
+2.2%
+12V2
0
12.26V
±5%
+2.2%
-12V
0
12.12V
±10%
+1.0%
+5VSB
0
5.16V
±5%
+3.2%
Total PSU DC Loading = 0W (0% of Rated Maximum Output Power)

 

Thermaltake Toughpower Grand 1200W (TPG-1200M) DC Output Voltage Load Regulation
Supply = 114VAC/50Hz
PSU DC Rail
Rail Loading
Measured Voltage
Permitted Regulation
Actual Regulation
+3.3V
3.16A
3.35V
±5%
+1.5%
+5V
4.69A
4.97V
±5%
-0.6%
+12V1
5.07A
12.19V
±5%
+1.6%
+12V2
10.62A
12.21V
±5%
+1.7%
-12V
0.35A
11.67V
±10%
-2.7%
+5VSB
2.18A
5.01V
±5%
+0.2%
Total PSU DC Loading = 240W (20% of Rated Maximum Output Power)

 

Thermaltake Toughpower Grand 1200W (TPG-1200M) DC Output Voltage Load Regulation
Supply = 111VAC/50Hz
PSU DC Rail
Rail Loading
Measured Voltage
Permitted Regulation
Actual Regulation
+3.3V
8.19A
3.29V
±5%
-0.3%
+5V
9.65A
4.91V
±5%
-1.8%
+12V1
16.07A
12.13V
±5%
+1.1%
+12V2
27.46A
12.13V
±5%
+1.1%
-12V
0.36A
11.85V
±10%
-1.2%
+5VSB
2.17A
4.93V
±5%
-1.4%
Total PSU DC Loading = 617W (51% of Rated Maximum Output Power)

 

Thermaltake Toughpower Grand 1200W (TPG-1200M) DC Output Voltage Load Regulation
Supply = 108VAC/50Hz
PSU DC Rail
Rail Loading
Measured Voltage
Permitted Regulation
Actual Regulation
+3.3V
13.28A
3.20
±5%
-3.0%
+5V
14.82A
4.82
±5%
-3.6%
+12V1
36.35A
12.05
±5%
+0.4%
+12V2
53.15A
12.05
±5%
+0.4%
-12V
0.36A
12.07
±10%
+0.6%
+5VSB
2.14A
4.88
±5%
-2.4%
Total PSU DC Loading = 1207W (101% of Rated Maximum Output Power)

 

Mains Input Voltage 230VAC

 

 

Thermaltake Toughpower Grand 1200W (TPG-1200M) DC Output Voltage Load Regulation
Supply = 244VAC/50Hz
PSU DC Rail
Rail Loading
Measured Voltage
Permitted Regulation
Actual Regulation
+3.3V
0
3.38
±5%
+2.4%
+5V
0
4.99
±5%
-0.2%
+12V1
0
12.26
±5%
+2.2%
+12V2
0
12.26
±5%
+2.2%
-12V
0
12.12
±10%
+1.0%
+5VSB
0
5.16
±5%
+3.2%
Total PSU DC Loading = 0W (0% of Rated Maximum Output Power)

 

Thermaltake Toughpower Grand 1200W (TPG-1200M) DC Output Voltage Load Regulation
Supply = 244VAC/50Hz
PSU DC Rail
Rail Loading
Measured Voltage
Permitted Regulation
Actual Regulation
+3.3V
3.15A
3.31V
±5%
+0.3%
+5V
4.71A
4.92V
±5%
-1.6%
+12V1
5.10A
12.21V
±5%
+1.7%
+12V2
10.63A
12.19V
±5%
+1.6%
-12V
0.35A
11.68V
±10%
-2.6%
+5VSB
2.18A
5.00V
±5%
0
Total PSU DC Loading = 240W (20% of Rated Maximum Output Power)

 

Thermaltake Toughpower Grand 1200W (TPG-1200M) DC Output Voltage Load Regulation
Supply = 241VAC/50Hz
PSU DC Rail
Rail Loading
Measured Voltage
Permitted Regulation
Actual Regulation
+3.3V
8.22A
3.28V
±5%
-0.6%
+5V
9.53A
4.90V
±5%
-2.0%
+12V1
15.91A
12.13V
±5%
+1.1%
+12V2
27.20A
12.13V
±5%
+1.1%
-12V
0.36A
11.76V
±10%
-2.0%
+5VSB
2.17A
4.94V
±5%
-1.2%
Total PSU DC Loading = 611W (51% of Rated Maximum Output Power)

 

Thermaltake Toughpower Grand 1200W (TPG-1200M) DC Output Voltage Load Regulation
Supply = 241VAC/50Hz
PSU DC Rail
Rail Loading
Measured Voltage
Permitted Regulation
Actual Regulation
+3.3V
12.92A
3.23V
±5%
-2.1%
+5V
14.51A
4.83V
±5%
-3.4%
+12V1
37.16A
12.05V
±5%
+0.4%
+12V2
54.01A
12.05V
±5%
+0.4%
-12V
0.36A
12.09V
±10%
+0.7%
+5VSB
2.14A
4.89V
±5%
-2.2%
Total PSU DC Loading = 1225W (102% of Rated Maximum Output Power)

 

The Thermaltake Toughpower Grand 1200W power supply produced a satisfactory set of results in this section with the regulation remaining well within the limits set down by the ATX12V V2.2 specification at all times so let's move on.




  1. Introduction & Closer Look
  2. Closer Look (The Power Supply)
  3. Specification & Features
  4. Testing: DC Voltage Load Regulation
  5. Testing: Efficiency, Power Factor & DC Quality
  6. Testing: Temperature, Noise Level & Fan Speed
  7. Conclusion