IN WIN Commander 1200W Power Supply Review
paulktreg - January 6, 2009» Discuss this article (1)
Testing:
For more information on how we test our power supplies, please browse our testing methodology.
Electrical Safety:
|
Electrical Safety Test Class 1
|
|
|
Manufacturer/Model
|
Pass/Fail
|
|
IN WIN Commander 1200W
|
Pass
|
Short Circuit Protection:
I short circuited the 3V3, 5V0 and all four 12V lines in turn. The power supply did shut down, and once the short was removed and the unit switched off for at least one second, resumed normal operation. Although listed here at the beginning of the testing section, I tend to leave this test until the very end, in case it doesn't quite go to plan.
DC Output Voltage Load Regulation:
Mains Input Voltage 110VAC
|
110VAC - Total Load at 214W which is 18% of Rated Maximum Output Power. |
|||||
|
PSU
DC Line
|
Measured
Voltage(V)
|
Measured
Current (A)
|
Load Power
(W)
|
ATX12V V Limits
(V)
|
Pass/Fail
|
|
+3V3
|
3.34
|
8.18
|
27.32
|
3.135 – 3.465
|
Pass
|
|
+5V0
|
5.07
|
9.22
|
46.74
|
4.75 – 5.25
|
Pass
|
|
+12V0(1)
|
12.07
|
2.56
|
30.90
|
11.4 – 12.6
|
Pass
|
|
+12V0(2)
|
12.10
|
2.58
|
31.22
|
11.4 – 12.6
|
Pass
|
|
+12V0(3)
|
12.10
|
2.56
|
30.98
|
11.4 – 12.6
|
Pass
|
|
+12V0(4)
|
12.07
|
2.59
|
31.26
|
11.4 – 12.6
|
Pass
|
|
-12V0
|
11.90
|
0.36
|
4.28
|
10.8 – 13.2
|
Pass
|
|
+5VSB
|
4.96
|
2.18
|
10.81
|
4.75 – 5.25
|
Pass
|
|
Total Power Supply Loading
|
214W
|
|
|||
|
110VAC - Total Load at 646W which is 54% of Rated Maximum Output Power. |
|||||
|
PSU
DC Line
|
Measured
Voltage(V)
|
Measured
Current (A)
|
Load Power
(W)
|
ATX12V V Limits
(V)
|
Pass/Fail
|
|
+3V3
|
3.34
|
8.10
|
27.05
|
3.135 – 3.465
|
Pass
|
|
+5V0
|
5.06
|
9.05
|
45.79
|
4.75 – 5.25
|
Pass
|
|
+12V0(1)
|
12.13
|
11.47
|
139.13
|
11.4 – 12.6
|
Pass
|
|
+12V0(2)
|
12.09
|
11.56
|
139.76
|
11.4 – 12.6
|
Pass
|
|
+12V0(3)
|
12.10
|
11.51
|
139.27
|
11.4 – 12.6
|
Pass
|
|
+12V0(4)
|
12.13
|
11.52
|
139.74
|
11.4 – 12.6
|
Pass
|
|
-12V0
|
12.12
|
0.37
|
4.48
|
10.8 – 13.2
|
Pass
|
|
+5VSB
|
4.95
|
2.18
|
10.79
|
4.75 – 5.25
|
Pass
|
|
Total Power Supply Loading
|
646W
|
|
|||
|
110VAC - Total Load at 1192W which is 99% of Rated Maximum Output Power. |
|||||
|
PSU
DC Line
|
Measured
Voltage(V)
|
Measured
Current (A)
|
Load Power
(W)
|
ATX12V V Limits
(V)
|
Pass/Fail
|
|
+3V3
|
3.33
|
12.73
|
42.40
|
3.135 – 3.465
|
Pass
|
|
+5V0
|
5.05
|
13.75
|
69.44
|
4.75 – 5.25
|
Pass
|
|
+12V0(1)
|
12.21
|
22.07
|
269.47
|
11.4 – 12.6
|
Pass
|
|
+12V0(2)
|
12.09
|
22.32
|
269.85
|
11.4 – 12.6
|
Pass
|
|
+12V0(3)
|
12.09
|
21.46
|
259.45
|
11.4 – 12.6
|
Pass
|
|
+12V0(4)
|
12.21
|
21.79
|
266.05
|
11.4 – 12.6
|
Pass
|
|
-12V0
|
12.33
|
0.38
|
4.68
|
10.8 – 13.2
|
Pass
|
|
+5VSB
|
4.94
|
2.18
|
10.77
|
4.75 – 5.25
|
Pass
|
|
Total Power Supply Loading
|
1192W
|
|
|||
Mains Input Voltage 230VAC
|
230VAC - Total Load at 213W which is 18% of Rated Maximum Output Power. |
|||||
|
PSU
DC Line
|
Measured
Voltage(V)
|
Measured
Current (A)
|
Load Power
(W)
|
ATX12V V Limits
(V)
|
Pass/Fail
|
|
+3V3
|
3.33
|
8.18
|
27.24
|
3.135 – 3.465
|
Pass
|
|
+5V0
|
5.06
|
9.12
|
46.15
|
4.75 – 5.25
|
Pass
|
|
+12V0(1)
|
12.07
|
2.56
|
30.90
|
11.4 – 12.6
|
Pass
|
|
+12V0(2)
|
12.10
|
2.58
|
31.22
|
11.4 – 12.6
|
Pass
|
|
+12V0(3)
|
12.10
|
2.55
|
30.85
|
11.4 – 12.6
|
Pass
|
|
+12V0(4)
|
12.07
|
2.59
|
31.26
|
11.4 – 12.6
|
Pass
|
|
-12V0
|
11.90
|
0.36
|
4.28
|
10.8 – 13.2
|
Pass
|
|
+5VSB
|
4.97
|
2.18
|
10.83
|
4.75 – 5.25
|
Pass
|
|
Total Power Supply Loading
|
213W
|
|
|||
|
230VAC - Total Load at 646W which is 54% of Rated Maximum Output Power. |
|||||
|
PSU
DC Line
|
Measured
Voltage(V)
|
Measured
Current (A)
|
Load Power
(W)
|
ATX12V V Limits
(V)
|
Pass/Fail
|
|
+3V3
|
3.34
|
8.12
|
27.12
|
3.135 – 3.465
|
Pass
|
|
+5V0
|
5.06
|
9.10
|
46.04
|
4.75 – 5.25
|
Pass
|
|
+12V0(1)
|
12.12
|
11.43
|
138.53
|
11.4 – 12.6
|
Pass
|
|
+12V0(2)
|
12.10
|
11.57
|
139.99
|
11.4 – 12.6
|
Pass
|
|
+12V0(3)
|
12.10
|
11.51
|
139.27
|
11.4 – 12.6
|
Pass
|
|
+12V0(4)
|
12.11
|
11.54
|
139.75
|
11.4 – 12.6
|
Pass
|
|
-12V0
|
12.11
|
0.37
|
4.48
|
10.8 – 13.2
|
Pass
|
|
+5VSB
|
4.95
|
2.18
|
10.79
|
4.75 – 5.25
|
Pass
|
|
Total Power Supply Loading
|
646W
|
|
|||
|
230VAC - Total Load at 1193W which is 99% of Rated Maximum Output Power. |
|||||
|
PSU
DC Line
|
Measured
Voltage(V)
|
Measured
Current (A)
|
Load Power
(W)
|
ATX12V V Limits
(V)
|
Pass/Fail
|
|
+3V3
|
3.34
|
12.73
|
42.52
|
3.135 – 3.465
|
Pass
|
|
+5V0
|
5.06
|
13.77
|
69.68
|
4.75 – 5.25
|
Pass
|
|
+12V0(1)
|
12.23
|
22.02
|
269.30
|
11.4 – 12.6
|
Pass
|
|
+12V0(2)
|
12.10
|
22.29
|
269.71
|
11.4 – 12.6
|
Pass
|
|
+12V0(3)
|
12.10
|
21.46
|
259.67
|
11.4 – 12.6
|
Pass
|
|
+12V0(4)
|
12.23
|
21.77
|
266.25
|
11.4 – 12.6
|
Pass
|
|
-12V0
|
12.35
|
0.38
|
4.69
|
10.8 – 13.2
|
Pass
|
|
+5VSB
|
4.94
|
2.18
|
10.77
|
4.75 – 5.25
|
Pass
|
|
Total Power Supply Loading
|
1193W
|
|
|||
The 12V1 and 12V2 rails are rated for 20A maximium so technically speaking they are overloaded. It's not going to prove anything, most power supplies will easily cope with 10% extra, so don't read too much into it. The IN WIN Commander 1200W performed very well in this section and all the DC rails remained at optimum levels even at almost 100% loading.

Facebook
Twitter
YouTube
RSS Feeds