Testing:

For more information on how we test our power supplies, please browse our testing methodology.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical Safety:

 

Electrical Safety Test Class 1
Manufacturer/Model
Pass/Fail
Corsair HX1000W
Pass

 

Short Circuit Protection:

I short circuited the 3V3, 5V0 and all two 12V lines in turn. The power supply did shut down, and once the short was removed and the unit switched off for at least one second, resumed normal operation. Although listed here at the beginning of the testing section, I tend to leave this test until the very end, in case it doesn't quite go to plan.

 

DC Output Voltage Load Regulation:

 

Testing @ 110VAC

 

 

110VAC - Total Load at 213W which is 21% of Rated Maximum Output Power.

PSU
DC Line
Measured
Voltage(V)
Measured
Current (A)
Load Power
(W)
ATX12V V Limits
(V)
Pass/Fail
+3V3
3.34
8.18
27.32
3.135 – 3.465
Pass
+5V0
5.05
9.39
47.42
4.75 – 5.25
Pass
+12V0(1)
12.08
5.12
61.85
11.4 – 12.6
Pass
+12V0(2)
12.02
5.16
62.02
11.4 – 12.6
Pass
-12V0
11.91
0.34
4.05
10.8 – 13.2
Pass
+5VSB
4.99
2.18
10.88
4.75 – 5.25
Pass
 Total Power Supply Loading
213W
 

 

110VAC - Total Load at 562W which is 56% of Rated Maximum Output Power.

PSU
DC Line
Measured
Voltage(V)
Measured
Current (A)
Load Power
(W)
ATX12V V Limits
(V)
Pass/Fail
+3V3
3.34
8.12
27.12
3.135 – 3.465
Pass
+5V0
5.05
9.34
47.17
4.75 – 5.25
Pass
+12V0(1)
12.07
19.79
238.86
11.4 – 12.6
Pass
+12V0(2)
12.01
19.47
233.83
11.4 – 12.6
Pass
-12V0
12.07
0.34
4.10
10.8 – 13.2
Pass
+5VSB
4.99
2.18
10.88
4.75 – 5.25
Pass
 Total Power Supply Loading
562W
 

 

110VAC - Total Load at 986W which is 99% of Rated Maximum Output Power.

PSU
DC Line
Measured
Voltage(V)
Measured
Current (A)
Load Power
(W)
ATX12V V Limits
(V)
Pass/Fail
+3V3
3.33
12.72
42.36
3.135 – 3.465
Pass
+5V0
5.05
14.00
70.70
4.75 – 5.25
Pass
+12V0(1)
12.07
35.75
431.50
11.4 – 12.6
Pass
+12V0(2)
12.02
35.49
426.59
11.4 – 12.6
Pass
-12V0
12.21
0.35
4.27
10.8 – 13.2
Pass
+5VSB
4.99
2.18
10.88
4.75 – 5.25
Pass
 Total Power Supply Loading
986W
 

 

Testing @ 230VAC

 

 

230VAC - Total Load at 213W which is 21% of Rated Maximum Output Power.

PSU
DC Line
Measured
Voltage(V)
Measured
Current (A)
Load Power
(W)
ATX12V V Limits
(V)
Pass/Fail
+3V3
3.33
8.17
27.21
3.135 – 3.465
Pass
+5V0
5.05
9.38
47.37
4.75 – 5.25
Pass
+12V0(1)
12.01
5.11
61.37
11.4 – 12.6
Pass
+12V0(2)
12.02
5.13
61.66
11.4 – 12.6
Pass
-12V0
11.90
0.34
4.05
10.8 – 13.2
Pass
+5VSB
4.98
2.18
10.86
4.75 – 5.25
Pass
 Total Power Supply Loading
213W
 

 

230VAC - Total Load at 563W which is 56% of Rated Maximum Output Power.

PSU
DC Line
Measured
Voltage(V)
Measured
Current (A)
Load Power
(W)
ATX12V V Limits
(V)
Pass/Fail
+3V3
3.33
8.08
26.91
3.135 – 3.465
Pass
+5V0
5.05
9.46
47.77
4.75 – 5.25
Pass
+12V0(1)
12.08
19.80
239.18
11.4 – 12.6
Pass
+12V0(2)
12.02
19.48
234.15
11.4 – 12.6
Pass
-12V0
12.07
0.34
4.10
10.8 – 13.2
Pass
+5VSB
4.99
2.18
10.88
4.75 – 5.25
Pass
 Total Power Supply Loading
563W
 

 

230VAC - Total Load at 988W which is 99% of Rated Maximum Output Power.

PSU
DC Line
Measured
Voltage(V)
Measured
Current (A)
Load Power
(W)
ATX12V V Limits
(V)
Pass/Fail
+3V3
3.33
12.63
42.06
3.135 – 3.465
Pass
+5V0
5.05
13.99
70.65
4.75 – 5.25
Pass
+12V0(1)
12.08
35.86
433.12
11.4 – 12.6
Pass
+12V0(2)
12.01
35.59
427.44
11.4 – 12.6
Pass
-12V0
12.20
0.35
4.27
10.8 – 13.2
Pass
+5VSB
4.99
2.18
10.88
4.75 – 5.25
Pass
 Total Power Supply Loading
988W
 

 

The DC output load regulation of the HX1000W is excellent and I have to say almost perfect. That says it all really!

 




  1. Introduction & Closer Look
  2. Closer Look (The Power Supply)
  3. Specification & Features
  4. Testing: DC Voltage Load Regulation At 110VAC & 230VAC
  5. Testing: Efficiency, Power Factor & DC Quality
  6. Testing: Temperature, Noise Level & Fan Speed
  7. Conclusion
Random Pic
© 2001-2014 Overclockers Club ® Privacy Policy

Also part of our network: TalkAndroid, Android Forum, iPhone Informer, Neoseeker, and Used Audio Classifieds

Elapsed: 0.0981888771